EMC design with high anti-jamming capability,suitable for industrial environment.
The DC24V power input circuit of weighing indicator has reverse polarity protection function.
Using 2 oil pressure sensors for getting higher weighing accuracy than using 1 oil pressure sensor
High sampling frequency, multiple digital filter and acceleration compensation algorithm for ensuring high weighing accuracy in the lifting process of the bucket
The display information of Bucket Lifting/Declining state, Date/Time and other auxiliary data are used for adjusting if Single-bucket-loading-weight is valid and the loading process should be stoped.
24-bit High-precision and high-speed ∑-A /D conversion module with 1,000,000 internal cod used and sampling frequency 400Hz
System Configuration:
1 Weighing Indicator.
2 Oil Pressure Sensors [0~25MPa].
2 Plate Type Three-way Joints.
1 Position Sensor [Detecting Distance: 5~8mm].
1 Thermal Printer.
1 Mounting Fitting.
System Accuracy:
Accuracy of Single-Bucket -Weight: 0.5%~1%FS.
Accuracy of Totalized Loading Weight: ±1.0% (OIML Y(b) Accuracy Grade).